Inflexible wire

Inflexible wire 5




Cenelec

H07V-U &H07V-R

Name in related standard

Single-core non-sheathed cable with rigid conductor for general purposes & Single-core non-sheathed cable with solid conductor for internal wiring for a conductor temperature of 70 °C

Nominal Voltage U0/U

300 / 500 V for conductors up to and including 1mm²

450 / 750 V for conductors above 1mm²

Reference standard

IEC 60227-3

Standard code

60227 IEC 05 ( H05V – U )
60227 IEC 01 ( H07V – U )
60227 IEC 01 ( H07V- R )

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

CU/PVC

Conductor material

Annealed copper conductor

PVC core insulation

PVC/ C

PVC outer sheath

*

Filler

*

Shield

*

Core insulation color

According to the customer’s request

Sheath color

*

1- Outdoor lighting installations.
2- EarthingIndoor or receiver installations.
3- Indoor installations in housing.

Nominal cross section of conductors (mm²) Conductor class The number and diameter of the nominal string of conductors Nominal insulation thickness (mm) Average overall dimensions (Lower limit) (mm) Average overall dimensions (Upper limit) (mm) Maximum ohmic resistance of the conductor at 20°C (Ω/km) The weight of a hundred meter coil (Kg)
0.5 1 1×0.8 0.6 1/9 2/3 36 8
0.75 1 1×0.95 0.6 2.1 2.5 24.5 11
1 1 1×1.12 0.6 2.2 2.7 18.1 13
1.5 1 1×1.33 0.7 2.6 3.2 12.1 19
1.5 2 7×0.52 0.8 2.7 3.3 12.1 21
2.5 1 1×1.74 0.8 3.2 3.9 7.41 30
2.5 2 7×0.66 0.8 3.3 4 7.41 33
4 1 1×2.19 0.8 3.6 4.4 4.61 44
4 2 7×0.82 0.8 3.8 4.6 4.61 48
6 1 1×2.76 0.8 4.1 5 3.08 62
6 2 7×1.01 0.8 4.3 5.2 3.08 67
10 1 1×3.51 1 5.3 6.4 1.83 104
10 2 7×1.33 1 5.6 6.7 1.83 111
16 2 7×1.7 1 6.4 7.6 1.15 169
25 2 7×2.12 1.2 8.1 9.7 0.727 264
35 2 7×2.46 1.2 9 10.9 0.524 354


Edit Table

Cenelec

H07V-U &H07V-R

Name in related standard

Single-core non-sheathed cable with rigid conductor for general purposes & Single-core non-sheathed cable with solid conductor for internal wiring for a conductor temperature of 70 °C

Nominal Voltage U0/U

300 / 500 V for conductors up to and including 1mm²

450 / 750 V for conductors above 1mm²

Reference standard

IEC 60227-3

Standard code

60227 IEC 05 ( H05V – U )
60227 IEC 01 ( H07V – U )
60227 IEC 01 ( H07V- R )

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

CU/PVC

Conductor material

Annealed copper conductor

PVC core insulation

PVC/ C

PVC outer sheath

*

Filler

*

Shield

*

Core insulation color

According to the customer’s request

Sheath color

*

1- Outdoor lighting installations.
2- EarthingIndoor or receiver installations.
3- Indoor installations in housing.

[ninja_tables id=”18982″]