Cenelec
NYSLCY
Name in related standard
Screened circular control cable, sheathed with PVC
Nominal Voltage U0/U
300 / 500 V for conductors up to and including 1mm²
450 / 750 V for conductors above 1mm²
Reference standard
IEC 60227-6
Standard code
۶۰۲۲۷ IEC 71C
Tempreture range
– 30℃ to + 70℃
Cable Layer Construction
Cu/PVC/PET/CWB/PVC
Conductor material
Flexible copper conductor according to IEC 60228, class 5.
PVC core insulation
Compound type of PVC/ D.
PVC outer sheath
Compound type of PVC/ ST5
Filler
*
Shield
Annealed copper conductor
Core insulation color
According to IEC 60227 – 1.
Sheath color
gray
1-These types of cables are used as link and connection control cables for machine tools, conveyor belts and plant
production lines, measuring and automatic control, computer units, construction equipments, power stations, cooling
and data processing systems and office machines. They are mostly installed in dry, damp or wet rooms at normal
stresses.
2-The copper braid serves as electromagnetic screen between the internal electric circuits and the environment,
therefore, it would eliminate any effects of electrical noises in the system.
| Nominal cross section of conductors (mm²) | Conductor class | The number and diameter of the nominal string of conductors | Nominal insulation thickness (mm) | Nominal thickness of the middle cover (mm) | Nominal diameter of shield conductors (mm) | Nominal sheath thickness (mm) | Average overall dimensions (Lower limit) (mm) | Average overall dimensions (Upper limit) (mm) | Maximum ohmic resistance of the conductor at 20°C (ohm/km) | Approximate weight (kg/km) |
|---|---|---|---|---|---|---|---|---|---|---|
| 2×0.5 | 5 | 24×0.193 | 0.6 | 0.7 | 0.15 | 0.9 | 7.7 | 9.6 | 39 | 71 |
| 2×0.75 | 5 | 24×0.193 | 0.6 | 0.7 | 0.15 | 0.9 | 8 | 10 | 26 | 79 |
| 2×1 | 5 | 31×0.193 | 0.6 | 0.7 | 0.15 | 0.9 | 8.2 | 10.3 | 19.5 | 83 |
| 2×1.5 | 5 | 30×0.235 | 0.7 | 0.7 | 0.15 | 1 | 9.3 | 11.6 | 13.3 | 105 |
| 2×2.5 | 5 | 50×0.235 | 0.8 | 0.7 | 0.15 | 0.9 | 8 | 10 | 39 | 76 |
| 3×0.5 | 5 | 16×0.193 | 0.6 | 0.7 | 0.15 | 0.9 | 8 | 10 | 39 | 76 |
| 3×1 | 5 | 31×0.193 | 0.6 | 0.7 | 0.15 | 1 | 8.8 | 11 | 19.5 | 98 |
| 3×0.75 | 5 | 24×0.193 | 0.6 | 0.7 | 0.15 | 0.9 | 8.3 | 10.4 | 26 | 90 |
| 3×2.5 | 5 | 50×0.235 | 0.8 | 0.7 | 0.15 | 1.1 | 11.3 | 14 | 7.98 | 175 |
| 3×1.5 | 5 | 30×0.235 | 0.7 | 0.7 | 0.15 | 1 | 9.7 | 12.1 | 13.3 | 126 |
| 4×0.5 | 5 | 16×0.193 | 0.6 | 0.7 | 0.15 | 0.9 | 8.5 | 10.7 | 39 | 90 |
| 4×0.75 | 5 | 24×0.193 | 0.6 | 0.7 | 0.15 | 1 | 9.1 | 11.3 | 26 | 105 |
| 4×1 | 5 | 31×0.193 | 0.6 | 0.7 | 0.15 | 1 | 9.4 | 11.7 | 19.5 | 117 |
| 4×1.5 | 5 | 30×0.235 | 0.7 | 0.7 | 0.15 | 1.1 | 10.7 | 13.2 | 13.3 | 155 |
| 4×2.5 | 5 | 50×0.235 | 0.8 | 0.8 | 0.15 | 1.2 | 12.6 | 15.5 | 7.98 | 220 |
| 5×0.5 | 5 | 16×0.193 | 0.6 | 0.7 | 0.15 | 1 | 9.3 | 11.6 | 39 | 106 |
| 5×0.75 | 5 | 24×0.193 | 0.6 | 0.7 | 0.15 | 1 | 9.7 | 12.1 | 26 | 123 |
| 5×1 | 5 | 31×0.193 | 0.6 | 0.7 | 0.15 | 1.1 | 10.3 | 12.8 | 19.5 | 142 |
| 5×1.5 | 5 | 30×0.235 | 0.7 | 0.8 | 0.15 | 1.2 | 11.8 | 14.7 | 13.3 | 190 |
| 5×2.5 | 5 | 50×0.235 | 0.8 | 0.8 | 0.2 | 1.3 | 13.9 | 17.2 | 7.98 | 275 |
| 6×0.5 | 5 | 16×0.193 | 0.6 | 0.7 | 0.15 | 1 | 9.9 | 12.4 | 39 | 120 |
| 6×0.75 | 5 | 24×0.193 | 0.6 | 0.7 | 0.15 | 1.1 | 10.5 | 13.1 | 26 | 145 |
| 6×1 | 5 | 31×0.193 | 0.6 | 0.7 | 0.15 | 1.1 | 11 | 13.6 | 19.5 | 160 |
| 6×1.5 | 5 | 30×0.235 | 0.7 | 0.8 | 0.15 | 1.2 | 12.7 | 15.7 | 13.3 | 220 |
| 6×2.5 | 5 | 50×0.235 | 0.8 | 0.8 | 0.2 | 1.4 | 15.2 | 18.7 | 7.98 | 323 |
| 7×0.5 | 5 | 16×0.193 | 0.6 | 0.7 | 0.15 | 1.1 | 10.8 | 13.5 | 39 | 140 |
| 7×0.75 | 5 | 24×0.193 | 0.6 | 0.7 | 0.15 | 1.2 | 11.5 | 14.3 | 26 | 165 |
| 7×1 | 5 | 31×0.193 | 0.6 | 0.8 | 0.15 | 1.2 | 12.2 | 15.1 | 19.5 | 190 |
| 7×1.5 | 5 | 30×0.235 | 0.7 | 0.8 | 0.2 | 1.3 | 14.1 | 17.4 | 13.3 | 260 |
| 7×2.5 | 5 | 50×0.235 | 0.8 | 0.8 | 0.2 | 1.5 | 16.5 | 20.3 | 7.98 | 275 |


Cenelec
NYSLCY
Name in related standard
Screened circular control cable, sheathed with PVC
Nominal Voltage U0/U
300 / 500 V for conductors up to and including 1mm²
450 / 750 V for conductors above 1mm²
Reference standard
IEC 60227-6
Standard code
۶۰۲۲۷ IEC 71C
Tempreture range
– 30℃ to + 70℃
Cable Layer Construction
Cu/PVC/PET/CWB/PVC
Conductor material
Flexible copper conductor according to IEC 60228, class 5.
PVC core insulation
Compound type of PVC/ D.
PVC outer sheath
Compound type of PVC/ ST5
Filler
*
Shield
Annealed copper conductor
Core insulation color
According to IEC 60227 – 1.
Sheath color
gray
1-These types of cables are used as link and connection control cables for machine tools, conveyor belts and plant
production lines, measuring and automatic control, computer units, construction equipments, power stations, cooling
and data processing systems and office machines. They are mostly installed in dry, damp or wet rooms at normal
stresses.
2-The copper braid serves as electromagnetic screen between the internal electric circuits and the environment,
therefore, it would eliminate any effects of electrical noises in the system.