Flat Lift Cables

Lifting




Cenelec

H05VV – F
H07VV – F

Name in related standard

Flat PVC sheathed lift cable and cable for flexible connections

Nominal Voltage U0/U

300 / 500 V for conductors up to and including 1mm²

450 / 750 V for conductors above 1mm²

Reference standard

IEC 60227-6

Standard code

۶۰۲۲۷ IEC 71F

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Flexible copper conductor according to IEC 60228, class 5.

PVC core insulation

Compound type of PVC/ D.

PVC outer sheath

Compound type of PVC / ST5.

Filler

*

Shield

*

Core insulation color

According to IEC 60227 – 1.

Sheath color

Sheath color is normally black, white or as per customer request.

1-These types of cables are often used as mobile cables for cranes, elevators and conveyor systems.

 2- These cables are suitable for use in indoor facilities and their advantages include high flexibility and minimal space requirement.

Cenelec

H05VV – F
H07VV – F

Name in related standard

Flat PVC sheathed lift cable and cable for flexible connections

Nominal Voltage U0/U

300 / 500 V for conductors up to and including 1mm²

450 / 750 V for conductors above 1mm²

Reference standard

IEC 60227-6

Standard code

۶۰۲۲۷ IEC 71F

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Flexible copper conductor according to IEC 60228, class 5.

PVC core insulation

Compound type of PVC/ D.

PVC outer sheath

Compound type of PVC / ST5.

Filler

*

Shield

*

Core insulation color

According to IEC 60227 – 1.

Sheath color

Sheath color is normally black, white or as per customer request.

1-These types of cables are often used as mobile cables for cranes, elevators and conveyor systems.

 2- These cables are suitable for use in indoor facilities and their advantages include high flexibility and minimal space requirement.

Light flexible cables

Light Inflexible cable 1




Cenelec

H03VV-F

Name in related standard

Light PVC sheathed cord

Nominal Voltage U0/U

300/300 v

Reference standard

IEC 60227-5

Standard code

60227 IEC 52

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Flexible copper conductor
according to IEC 60228, class 5

PVC core insulation

Compound type of PVC /D

PVC outer sheath

Compound type of PVC / ST5

Filler

*

Shield

*

Core insulation color

According to IEC 60227 – 1

Sheath color

Sheath color is normally black, white or as per customer request.

1-These types of cables are used as extensions and connecting cables for electrical devices,
2-appliances and machinery where plugs must be permanently connected to the corresponding cables.
Examples: kitchen utensils, desk lamps, floor lamps, vacuum cleaners, office machines, radios and etc. These cables are not permitted to be used for cooking or heating appliances, also they are not suitable for outdoor and industrial use or farming machinery.


Nominal cross section of conductors (mm²) Conductor class The number and diameter of the nominal string of conductors Nominal insulation thickness (mm) Nominal sheath thickness (mm) Average overall dimensions (Lower limit) (mm) Average overall dimensions (Upper limit) (mm) Maximum ohmic resistance of the conductor at 20°C (ohm/km) Approximate weight (kg/km)
2×0.5 5 16×0.193 0.5 0.6 4.6 5.9 39 37
2×0.5 Flat 5 16×0.193 0.5 0.6 4.9×3 5.9×3.7 39 24
2×0.75 5 24×0.193 0.5 0.6 4.9 6.3 26 45
2×0.75 Flat 5 24×0.193 0.5 0.6 5.2×3.2 6.3×3.8 26 30
3×0.5 5 16×0.193 0.5 0.6 4.9 6.3 39 43
3×0.75 5 24×0.193 0.5 0.6 5.2 6.7 26 55


Edit Table

Cenelec

H03VV-F

Name in related standard

Light PVC sheathed cord

Nominal Voltage U0/U

300/300 v

Reference standard

IEC 60227-5

Standard code

60227 IEC 52

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Flexible copper conductor
according to IEC 60228, class 5

PVC core insulation

Compound type of PVC /D

PVC outer sheath

Compound type of PVC / ST5

Filler

*

Shield

*

Core insulation color

According to IEC 60227 – 1

Sheath color

Sheath color is normally black, white or as per customer request.

1-These types of cables are used as extensions and connecting cables for electrical devices,
2-appliances and machinery where plugs must be permanently connected to the corresponding cables.
Examples: kitchen utensils, desk lamps, floor lamps, vacuum cleaners, office machines, radios and etc. These cables are not permitted to be used for cooking or heating appliances, also they are not suitable for outdoor and industrial use or farming machinery.

[ninja_tables id=”18843″]

Circular Lift Cables

Circular 1




Cenelec

H05VV – F
H07VV – F

Name in related standard

Circular PVC sheathed lift cable and cable for flexible connections

Nominal Voltage U0/U

300 / 500 V for conductors up to and including 1mm²

450 / 750 V for conductors above 1mm²

Reference standard

IEC 60227-6

Standard code

۶۰۲۲۷ IEC 71C

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Flexible copper conductor according to IEC 60228, class 5.

PVC core insulation

Compound type of PVC/ D.

PVC outer sheath

Compound type of PVC / ST5.

Filler

*

Shield

*

Core insulation color

According to IEC 60227 – 1.

Sheath color

Sheath color is normally black, white or as per customer request.

1-These types of cables are often used as mobile cables for cranes, elevators and conveyor systems.
2- These cables are suitable for use in indoor facilities and their advantages include high flexibility and minimal space requirement.

Nominal cross section of conductors (mm²) Conductor class The number and diameter of the nominal string of conductors Nominal insulation thickness (mm) Nominal diameter of insulation (mm) Assumed diameter wire (mm) K Assumed diameter under the sheath (mm) Nominal sheath thickness (mm) Average overall dimensions (mm) Maximum ohmic resistance of the conductor at 20°C (ohm/km) Approximate weight (kg/km)
2×1.5 5 30×0.235 0.7 3 1.4 2 5.6 1 8 13.3 88
2×2.5 5 50×0.235 0.8 3.6 1.8 2 6.8 1 9.2 7.98 125
2×4 5 56×0.285 0.8 4.2 2.3 2 7.8 1 10.4 4.95 165
2×6 5 84×0.285 0.8 4.8 2.8 2 8.8 1 11.6 3.3 216
2×10 5 144×0.285 1 6.1 3.6 2 11.2 1.3 14.8 1.91 380
2×16 5 224×0.285 1 7.2 4.5 2 13 1.3 17 1.21 512
2×25 5 301×0.306 1.2 8.8 5.6 2 16 1.6 20.8 0.78 731
3×2.5 5 50×0.235 0.8 3.6 1.8 2.16 7.3 1 9.8 7.98 158
3×4 5 56×0.285 0.8 4.2 2.3 2.16 8.4 1 11.1 4.95 212
3×6 5 84×0.285 0.8 4.8 2.8 2.16 9.5 1.3 13 3.3 290
3×10 5 144×0.285 1 6.1 3.6 2.16 12.1 1.3 15.8 1.91 493
3×16 5 224×0.285 1 7.2 4.5 2.16 14 1.3 18.2 1.21 712
3×25 5 301×0.306 1.2 8.8 5.6 2.16 17.3 1.6 22.2 0.78 1020
4×1.5 5 30×0.235 0.7 3 1.4 2.42 6.8 1 9.3 13.3 130
4×2.5 5 50×0.235 0.8 3.6 1.8 2.42 8.2 1 10.7 7.98 190
4×4 5 56×0.285 0.8 4.2 2.3 2.42 9.4 1.3 12.8 4.95 280
4×6 5 84×0.285 0.8 4.8 2.8 2.42 10.6 1.3 14.2 3.3 360
4×10 5 144×0.285 1 6.1 3.6 2.42 13.6 1.3 17.4 1.91 620
4×16 5 224×0.285 1 7.2 4.5 2.42 15.7 1.6 20.6 1.21 925
4×25 5 301×0.306 1.2 8.8 5.6 2.42 19.4 2 25.3 0.78 1310
5×1.5 5 30×0.235 0.7 3 1.4 2.7 7.6 1 10.1 13.3 156
5×2.5 5 50×0.235 0.8 3.6 1.8 2.7 9.2 1.3 12.3 7.98 245
5×4 5 56×0.285 0.8 4.2 2.3 2.7 10.5 1.3 13.9 4.95 340
5×6 5 84×0.285 0.8 4.8 2.8 2.7 11.9 1.3 15.6 3.3 445
5×10 5 144×0.285 1 6.1 3.6 2.7 15.1 1.6 19.7 1.91 750
5×16 5 224×0.285 1 7.2 4.5 2.7 17.6 1.6 22.6 1.21 1115
5×25 5 301×0.306 1.2 8.8 5.6 2.7 21.6 2 27.8 0.78 1570


Edit Table

Cenelec

H05VV – F
H07VV – F

Name in related standard

Circular PVC sheathed lift cable and cable for flexible connections

Nominal Voltage U0/U

300 / 500 V for conductors up to and including 1mm²

450 / 750 V for conductors above 1mm²

Reference standard

IEC 60227-6

Standard code

۶۰۲۲۷ IEC 71C

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Flexible copper conductor according to IEC 60228, class 5.

PVC core insulation

Compound type of PVC/ D.

PVC outer sheath

Compound type of PVC / ST5.

Filler

*

Shield

*

Core insulation color

According to IEC 60227 – 1.

Sheath color

Sheath color is normally black, white or as per customer request.

1-These types of cables are often used as mobile cables for cranes, elevators and conveyor systems.
2- These cables are suitable for use in indoor facilities and their advantages include high flexibility and minimal space requirement.

[ninja_tables id=”19002″]