Screened Flexible Control Cables

Shield 3




Cenelec

NYSLCY

Name in related standard

Screened circular control cable, sheathed with PVC

Nominal Voltage U0/U

300 / 500 V for conductors up to and including 1mm²

450 / 750 V for conductors above 1mm²

Reference standard

IEC 60227-6

Standard code

۶۰۲۲۷ IEC 71C

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PET/CWB/PVC

Conductor material

Flexible copper conductor according to IEC 60228, class 5.

PVC core insulation

Compound type of PVC/ D.

PVC outer sheath

Compound type of PVC/ ST5

Filler

*

Shield

Annealed copper conductor

Core insulation color

According to IEC 60227 – 1.

Sheath color

 gray

1-These types of cables are used as link and connection control cables for machine tools, conveyor belts and plant
production lines, measuring and automatic control, computer units, construction equipments, power stations, cooling
and data processing systems and office machines. They are mostly installed in dry, damp or wet rooms at normal
stresses.
2-The copper braid serves as electromagnetic screen between the internal electric circuits and the environment,
therefore, it would eliminate any effects of electrical noises in the system.


Nominal cross section of conductors (mm²) Conductor class The number and diameter of the nominal string of conductors Nominal insulation thickness (mm) Nominal thickness of the middle cover (mm) Nominal diameter of shield conductors (mm) Nominal sheath thickness (mm) Average overall dimensions (Lower limit) (mm) Average overall dimensions (Upper limit) (mm) Maximum ohmic resistance of the conductor at 20°C (ohm/km) Approximate weight (kg/km)
2×0.5 5 24×0.193 0.6 0.7 0.15 0.9 7.7 9.6 39 71
2×0.75 5 24×0.193 0.6 0.7 0.15 0.9 8 10 26 79
2×1 5 31×0.193 0.6 0.7 0.15 0.9 8.2 10.3 19.5 83
2×1.5 5 30×0.235 0.7 0.7 0.15 1 9.3 11.6 13.3 105
2×2.5 5 50×0.235 0.8 0.7 0.15 0.9 8 10 39 76
3×0.5 5 16×0.193 0.6 0.7 0.15 0.9 8 10 39 76
3×1 5 31×0.193 0.6 0.7 0.15 1 8.8 11 19.5 98
3×0.75 5 24×0.193 0.6 0.7 0.15 0.9 8.3 10.4 26 90
3×2.5 5 50×0.235 0.8 0.7 0.15 1.1 11.3 14 7.98 175
3×1.5 5 30×0.235 0.7 0.7 0.15 1 9.7 12.1 13.3 126
4×0.5 5 16×0.193 0.6 0.7 0.15 0.9 8.5 10.7 39 90
4×0.75 5 24×0.193 0.6 0.7 0.15 1 9.1 11.3 26 105
4×1 5 31×0.193 0.6 0.7 0.15 1 9.4 11.7 19.5 117
4×1.5 5 30×0.235 0.7 0.7 0.15 1.1 10.7 13.2 13.3 155
4×2.5 5 50×0.235 0.8 0.8 0.15 1.2 12.6 15.5 7.98 220
5×0.5 5 16×0.193 0.6 0.7 0.15 1 9.3 11.6 39 106
5×0.75 5 24×0.193 0.6 0.7 0.15 1 9.7 12.1 26 123
5×1 5 31×0.193 0.6 0.7 0.15 1.1 10.3 12.8 19.5 142
5×1.5 5 30×0.235 0.7 0.8 0.15 1.2 11.8 14.7 13.3 190
5×2.5 5 50×0.235 0.8 0.8 0.2 1.3 13.9 17.2 7.98 275
6×0.5 5 16×0.193 0.6 0.7 0.15 1 9.9 12.4 39 120
6×0.75 5 24×0.193 0.6 0.7 0.15 1.1 10.5 13.1 26 145
6×1 5 31×0.193 0.6 0.7 0.15 1.1 11 13.6 19.5 160
6×1.5 5 30×0.235 0.7 0.8 0.15 1.2 12.7 15.7 13.3 220
6×2.5 5 50×0.235 0.8 0.8 0.2 1.4 15.2 18.7 7.98 323
7×0.5 5 16×0.193 0.6 0.7 0.15 1.1 10.8 13.5 39 140
7×0.75 5 24×0.193 0.6 0.7 0.15 1.2 11.5 14.3 26 165
7×1 5 31×0.193 0.6 0.8 0.15 1.2 12.2 15.1 19.5 190
7×1.5 5 30×0.235 0.7 0.8 0.2 1.3 14.1 17.4 13.3 260
7×2.5 5 50×0.235 0.8 0.8 0.2 1.5 16.5 20.3 7.98 275


Edit Table

Cenelec

NYSLCY

Name in related standard

Screened circular control cable, sheathed with PVC

Nominal Voltage U0/U

300 / 500 V for conductors up to and including 1mm²

450 / 750 V for conductors above 1mm²

Reference standard

IEC 60227-6

Standard code

۶۰۲۲۷ IEC 71C

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PET/CWB/PVC

Conductor material

Flexible copper conductor according to IEC 60228, class 5.

PVC core insulation

Compound type of PVC/ D.

PVC outer sheath

Compound type of PVC/ ST5

Filler

*

Shield

Annealed copper conductor

Core insulation color

According to IEC 60227 – 1.

Sheath color

 gray

1-These types of cables are used as link and connection control cables for machine tools, conveyor belts and plant
production lines, measuring and automatic control, computer units, construction equipments, power stations, cooling
and data processing systems and office machines. They are mostly installed in dry, damp or wet rooms at normal
stresses.
2-The copper braid serves as electromagnetic screen between the internal electric circuits and the environment,
therefore, it would eliminate any effects of electrical noises in the system.

[ninja_tables id=”19000″]

Flexible cables

Flexible cable 1




Cenelec

H05VV-F

Name in related standard

Ordinary PVC sheathed cord

Nominal Voltage U0/U

300/500 v

Reference standard

IEC 60227-5

Standard code

60227 IEC 53

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Flexible copper conductor according to IEC 60228, class 5.

PVC core insulation

Compound type of PVC/ D.

PVC outer sheath

Compound type of PVC / ST5.

Filler

*

Shield

*

Core insulation color

According to IEC 60227 – 1.

Sheath color

Sheath color is normally black, white or as per customer request.

1-Indoor installations in housing.
2-Premises that contain a bath or shower.
3-These types of cables are used in applications such as extensions and connecting cables for electrical devices,
appliances and machinery where plugs must be permanently connected to the corresponding cables.
4-Any direct cable contact with hot parts of cooking and heating appliances and also any other heat influences is
prohibited.

Nominal cross section of conductors (mm²) Conductor class The number and diameter of the nominal string of conductors Nominal insulation thickness (mm) Nominal sheath thickness (mm) Average overall dimensions (Lower limit) (mm) Average overall dimensions (Upper limit) (mm) Maximum ohmic resistance of the conductor at 20°C (ohm/km) Approximate weight (kg/km)
2×0.75 5 24×0.193 0.6 0.8 5.7 7.2 24.5 55
2×0.75 Flat 5 24×0.193 0.6 0.8 3.7×6 4.5×7.2 24.5 44
2×1 5 31×0.193 0.6 0.8 5.9 7.5 19.5 65
2×1 Flat 5 31×0.193 0.6 0.8 3.9×6.2 4.7×7.5 19.5 55
2×1.5 5 30×0.235 0.7 0.8 6.8 8.6 13.3 85
2×2.5 5 50×0.235 0.8 1 8.4 10.6 7.98 125
2×4 5 56×0.285 0.8 1.1 9.7 12.1 4.95 170
3×0.75 5 24×0.193 0.6 0.8 6 7.6 24.5 64
3×1 5 31×0.193 0.6 0.8 6.3 8 19.5 75
3×2.5 5 50×0.235 0.8 1.1 9.2 11.4 7.98 160
3×1.5 5 30×0.235 0.7 0.9 7.4 9.4 13.3 105
3×4 5 56×0.285 0.8 1.1 10.3 12.8 4.95 215
4×0.75 5 24×0.193 0.6 0.8 6.6 8.3 24.5 75
4×1 5 31×0.193 0.6 0.9 7.1 9 19.5 93
4×1.5 5 30×0.235 0.7 1 8.4 10.5 13.3 130
4×2.5 5 50×0.235 0.8 1.1 10.1 12.5 7.98 195
4×4 5 56×0.285 0.8 1.2 11.5 14.3 4.95 272
5×0.75 5 24×0.193 0.6 0.9 7.4 9.3 24.5 100
5×1 5 31×0.193 0.6 0.9 7.8 9.8 19.5 112
5×1.5 5 30×0.235 0.7 1.1 9.3 11.6 13.3 160
5×2.5 5 50×0.235 0.8 1.2 11.2 13.9 7.98 240
5×4 5 56×0.285 0.8 1.3 12.8 15.9 4.95 340


Edit Table

Cenelec

H05VV-F

Name in related standard

Ordinary PVC sheathed cord

Nominal Voltage U0/U

300/500 v

Reference standard

IEC 60227-5

Standard code

60227 IEC 53

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Flexible copper conductor according to IEC 60228, class 5.

PVC core insulation

Compound type of PVC/ D.

PVC outer sheath

Compound type of PVC / ST5.

Filler

*

Shield

*

Core insulation color

According to IEC 60227 – 1.

Sheath color

Sheath color is normally black, white or as per customer request.

1-Indoor installations in housing.
2-Premises that contain a bath or shower.
3-These types of cables are used in applications such as extensions and connecting cables for electrical devices,
appliances and machinery where plugs must be permanently connected to the corresponding cables.
4-Any direct cable contact with hot parts of cooking and heating appliances and also any other heat influences is
prohibited.

[ninja_tables id=”18995″]

Flexible Power Cables

Flexible Power 02




Cenelec

NYY R
NYY U

Name in related standard

Single Core Power Cables

Nominal Voltage U0/U

0.6/1 KV

Reference standard

IEC 60502 – 1

Standard code

IEC 60502 – 1

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Annealed copper conductor according to IEC 60228, class 1 ( solid ), class 2 ( stranded ).

PVC core insulation

Compound type of PVC/ A.

PVC outer sheath

Compound type of PVC / ST1.

Filler

*

Shield

*

Core insulation color

Core insulation color is normally black.

Sheath color

Sheath color is normally black. According to the customer’s request.

These types of cables are used for distribution of electrical energy for fixed installations in underground, cable
ducts, indoors, in water and open air where mechanical damages are not expected.


Nominal cross section of conductors mm2 Conductor class The number and diameter of the nominal string of conductors Nominal insulation thickness mm Nominal diameter of insulation
mm
k Minimum sheath thickness
(mm)
Average overall dimensions
mm
Maximum ohmic resistance of the conductor at 20°C Ω/km
2*1.5 5 30*0.235 0.8 3.2 2 1.24 9.1 13.3
2*2.5 5 50*0.235 0.8 3.6 2 1.24 9.9 7.98
2*4 5 56*0.285 1 4.6 2 1.24 11.9 4.95
2*6 5 84*0.285 1 5.2 2 1.24 13.1 3.3
2*10 5 144*0.285 1 6.1 2 1.24 14.9 1.91
2*16 5 224*0.285 1 7.2 2 1.24 17.1 1.21
2*25 5 301*0.306 1.2 8.8 2 1.24 20.3 0.78
2*35 5 301*0.306 1.2 10.2 2.16 1.24 24.7 0.78
3*1.5 5 30*0.235 0.8 3.2 2.16 1.24 9.6 13.3
3*2.5 5 50*0.235 0.8 3.6 2.16 1.24 10.5 7.98
3*4 5 56*0.285 1 4.6 2.16 1.24 12.6 4.95
3*6 5 84*0.285 1 5.2 2.16 1.24 13.9 3.3
3*10 5 144*0.285 1 6.1 2.16 1.24 15.9 1.91
3*16 5 224*0.285 1 7.2 2.16 1.24 18.2 1.21
3*25 5 301*0.306 1.2 8.8 2.42 1.24 24.0 0.78
3*35 5 427*0.306 1.2 10.2 2.42 1.24 27.4 0.554
3*25/16 5 301*0.306 | 224*0.285 1.2-1 8.8-7.2 2.42 1.24 23.2 0.78-1.21
3*35/16 5 427*0.306 | 224*0.285 1.2-1 10.2-7.2 2.42 1.24 25.7 0.554-1.21
4*1.5 5 30*0.235 0.8 3.2 2.42 1.24 10.4 13.3
4*2.5 5 50*0.235 0.8 3.6 2.42 1.24 11.4 7.98
4*4 5 56*0.285 1 4.6 2.42 1.24 13.8 4.95
4*6 5 84*0.285 1 5.2 2.7 1.24 16.7 3.3
4*10 5 144*0.285 1 6.1 2.7 1.24 19.2 1.91
4*16 5 224*0.285 1 7.2 2.7 1.24 22.1 1.21
4*25 5 301*0.306 1.2 8.8 2.7 1.24 26.4 0.78
5*1.5 5 30*0.235 0.8 3.2 2.7 1.24 11.3 13.3
5*2.5 5 50*0.235 0.8 3.6 2.7 1.24 12.4 7.98
5*4 5 56*0.285 1 4.6 2.7 1.24 15.1 4.95
5*6 5 84*0.285 1 5.2 2.7 1.24 16.7 3.3
5*10 5 144*0.285 1 6.1 2.7 1.24 19.2 1.91
5*16 5 224*0.285 1 7.2 2.7 1.24 22.1 1.21
5*25 5 301*0.306 1.2 8.8 2.7 1.24 26.4 0.78


Edit Table

Cenelec

NYY R
NYY U

Name in related standard

Single Core Power Cables

Nominal Voltage U0/U

0.6/1 KV

Reference standard

IEC 60502 – 1

Standard code

IEC 60502 – 1

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Annealed copper conductor according to IEC 60228, class 1 ( solid ), class 2 ( stranded ).

PVC core insulation

Compound type of PVC/ A.

PVC outer sheath

Compound type of PVC / ST1.

Filler

*

Shield

*

Core insulation color

Core insulation color is normally black.

Sheath color

Sheath color is normally black. According to the customer’s request.

These types of cables are used for distribution of electrical energy for fixed installations in underground, cable
ducts, indoors, in water and open air where mechanical damages are not expected.

[ninja_tables id=”19058″]