Flexible Power Cables

Flexible Power 02




Cenelec

NYY R
NYY U

Name in related standard

Single Core Power Cables

Nominal Voltage U0/U

0.6/1 KV

Reference standard

IEC 60502 – 1

Standard code

IEC 60502 – 1

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Annealed copper conductor according to IEC 60228, class 1 ( solid ), class 2 ( stranded ).

PVC core insulation

Compound type of PVC/ A.

PVC outer sheath

Compound type of PVC / ST1.

Filler

*

Shield

*

Core insulation color

Core insulation color is normally black.

Sheath color

Sheath color is normally black. According to the customer’s request.

These types of cables are used for distribution of electrical energy for fixed installations in underground, cable
ducts, indoors, in water and open air where mechanical damages are not expected.


Nominal cross section of conductors mm2 Conductor class The number and diameter of the nominal string of conductors Nominal insulation thickness mm Nominal diameter of insulation
mm
k Minimum sheath thickness
(mm)
Average overall dimensions
mm
Maximum ohmic resistance of the conductor at 20°C Ω/km
2*1.5 5 30*0.235 0.8 3.2 2 1.24 9.1 13.3
2*2.5 5 50*0.235 0.8 3.6 2 1.24 9.9 7.98
2*4 5 56*0.285 1 4.6 2 1.24 11.9 4.95
2*6 5 84*0.285 1 5.2 2 1.24 13.1 3.3
2*10 5 144*0.285 1 6.1 2 1.24 14.9 1.91
2*16 5 224*0.285 1 7.2 2 1.24 17.1 1.21
2*25 5 301*0.306 1.2 8.8 2 1.24 20.3 0.78
2*35 5 301*0.306 1.2 10.2 2.16 1.24 24.7 0.78
3*1.5 5 30*0.235 0.8 3.2 2.16 1.24 9.6 13.3
3*2.5 5 50*0.235 0.8 3.6 2.16 1.24 10.5 7.98
3*4 5 56*0.285 1 4.6 2.16 1.24 12.6 4.95
3*6 5 84*0.285 1 5.2 2.16 1.24 13.9 3.3
3*10 5 144*0.285 1 6.1 2.16 1.24 15.9 1.91
3*16 5 224*0.285 1 7.2 2.16 1.24 18.2 1.21
3*25 5 301*0.306 1.2 8.8 2.42 1.24 24.0 0.78
3*35 5 427*0.306 1.2 10.2 2.42 1.24 27.4 0.554
3*25/16 5 301*0.306 | 224*0.285 1.2-1 8.8-7.2 2.42 1.24 23.2 0.78-1.21
3*35/16 5 427*0.306 | 224*0.285 1.2-1 10.2-7.2 2.42 1.24 25.7 0.554-1.21
4*1.5 5 30*0.235 0.8 3.2 2.42 1.24 10.4 13.3
4*2.5 5 50*0.235 0.8 3.6 2.42 1.24 11.4 7.98
4*4 5 56*0.285 1 4.6 2.42 1.24 13.8 4.95
4*6 5 84*0.285 1 5.2 2.7 1.24 16.7 3.3
4*10 5 144*0.285 1 6.1 2.7 1.24 19.2 1.91
4*16 5 224*0.285 1 7.2 2.7 1.24 22.1 1.21
4*25 5 301*0.306 1.2 8.8 2.7 1.24 26.4 0.78
5*1.5 5 30*0.235 0.8 3.2 2.7 1.24 11.3 13.3
5*2.5 5 50*0.235 0.8 3.6 2.7 1.24 12.4 7.98
5*4 5 56*0.285 1 4.6 2.7 1.24 15.1 4.95
5*6 5 84*0.285 1 5.2 2.7 1.24 16.7 3.3
5*10 5 144*0.285 1 6.1 2.7 1.24 19.2 1.91
5*16 5 224*0.285 1 7.2 2.7 1.24 22.1 1.21
5*25 5 301*0.306 1.2 8.8 2.7 1.24 26.4 0.78


Edit Table

Cenelec

NYY R
NYY U

Name in related standard

Single Core Power Cables

Nominal Voltage U0/U

0.6/1 KV

Reference standard

IEC 60502 – 1

Standard code

IEC 60502 – 1

Tempreture range

– 30℃ to + 70℃

Cable Layer Construction

Cu/PVC/PVC

Conductor material

Annealed copper conductor according to IEC 60228, class 1 ( solid ), class 2 ( stranded ).

PVC core insulation

Compound type of PVC/ A.

PVC outer sheath

Compound type of PVC / ST1.

Filler

*

Shield

*

Core insulation color

Core insulation color is normally black.

Sheath color

Sheath color is normally black. According to the customer’s request.

These types of cables are used for distribution of electrical energy for fixed installations in underground, cable
ducts, indoors, in water and open air where mechanical damages are not expected.

[ninja_tables id=”19058″]