Indoor telephone cables
Specifications and structure of indoor (aerial) telecommunication cables, according to NOOR wire and cable catalog.
Product features
- Technical code
- J2Y (St) Y
IEC 60189
VDE 0816
J2Y (St) Y - Temperature range (°C)
- to +5 C
+40 C
PVC
500 V (AC)
: Maximum conductor resistance
For 101 / KM : 0.5
: Mutual capacitance
52 + 4 nf / Km - Minimum insulation resistance
- 20,000 M.Km
- Structure of layers
- Cu / HDPE / OSCR / PVC
General description and specifications
Telephone cables for indoor wiring with insulation
and aluminum cover and shield
HDPE
: Maximum operating voltage
300 v
: Nominal voltage
Cable code:
IEC 60189
VDE 0816
J2Y (St) Y
: Temperature range
to +5 C
+40 C
PVC
500 V (AC)
: Maximum conductor resistance
For 101 / KM: 0.5
: Mutual capacitance
52 + 4 nf / Km
: Minimum insulation resistance
20,000 M.Km
: reference standard
Wire and cable structure
Wire structure
Coating material: mixed type
Cu/HDPE/OSCR/PVC
Wire 1, conductor material and class: annealed copper class
, and 5 or 4 types of insulating material: mix of brigade, class, group
According to the standard
PE
Identification of strands: two strands according to the standard color scheme to each other
radiated and form a couple. Then couples to each other
spun and a layer of polyester tape longitudinally or transversely for
An increase in insulation resistance is placed on them
PVC
Shield: An aluminum layer longitudinally or transversely as a shield
In contact with a single strand of plain copper or tin plated
Cover color: gray
YM1
B
III
E8
ASTM D - 1248
Applications
Main application in building
Internal distribution wire: connecting the building's input terminal to the outlet inside the units
Intercom and iPhone wire: internal wiring for audio and video system
Small local area network: use as a part of telecommunication infrastructures in the office and home that require high flexibility
Technical specification table
| Product type | Nominal diameter of the conductormm | Insulation type | Insulation thicknessmm | Coating thicknessmm | Average outer diametermm | Approximate weightkg/km |
|---|---|---|---|---|---|---|
| 2 x 2 x 0.6 | 0.6 | HDPE | 0.2 | 0.8 | 4.8 | 29 |
| 4 x 2 x 0.6 | 0.6 | HDPE | 0.2 | 0.8 | 6.1 | 45 |
| 6 x 2 x 0.6 | 0.6 | HDPE | 0.2 | 0.8 | 6.7 | 60 |
| 10 x 2 x 0.6 | 0.6 | HDPE | 0.2 | 1 | 8.1 | 90 |