Solid and stranded wires
Specifications and structure of stranded and semi-conductive wires, according to NOOR wire and cable catalog.
Product features
- Technical code
- H05V-U ، H07V-U ، H07V - R ، NYA
ISIRI (607) 01
IEC 60227 05 (H05V - U)
IEC 60227 01 (H07V - U)
IEC 60227 01 (H07V - R)
NYA - Rated voltage (V)
- For conductors up to 300 / 500 v
1 mm2
For conductors with a cross section greater than 450 / 750 v
1 mm2 - Reference standard
- ISIRI 607 - 3
ISIRI 60227 - 3 - Temperature range (°C)
- to-5 C
+70 C - Structure of layers
- Cu / PVC
General description and specifications
Wire and semi-insulated wires with insulation
PVC
: Nominal voltage
For conductors up to 300 / 500 v
1 mm2
For conductors with a cross section greater than 450 / 750 v
1 mm2
: reference standard
ISIRI 607 - 3
ISIRI 60227 - 3
: SIM code
ISIRI (607) 01
IEC 60227 05 (H05V - U)
IEC 60227 01 (H07V - U)
IEC 60227 01 (H07V - R)
N.Y.A
: Temperature range
to-5 C
+70 C
Wire and cable structure
Wire structure
Cu/PVC
(Maftoli), for conductor 1, conductor type and grade: grade annealed copper
(semi-expanded) for 2 kidneys up to cross-sectional level and class
Conductor sizes, according to the national standard (IEC 60228) ISIRI 3084
Insulation material: mixed type
PVC
c
Insulation coloring: according to customer request
16 mm2
Applications
wire
. Simple production process 4. Low cost 3. Mechanical strength 2. Electrical conductivity 1: an obvious feature
Fixed wiring of the building
Talu industrial electricity distribution
Power transmission lines
Network cable
Semi-conductive wire
Feature: balance and shaping
Electrical switchboard connections - installation in ducts and trays - constant pressure electrical cables - fixed industrial equipment
Technical specification table
| Nominal cross-sectional area of the conductormm² | Conductor class | Number and diameter of conductor strands | Nominal thickness of insulationmm | Lower limit of overall dimensionsmm | Upper limit of overall dimensionsmm | Maximum conductor ohmic resistance at ۲۰°CΩ/km | Approximate weightkg/km |
|---|---|---|---|---|---|---|---|
| 0.5 | 1 | 1 x 0.8 | 0.6 | 1.9 | 2.3 | 36 | 8 |
| 0.75 | 1 | 1 x 0.95 | 0.6 | 2.1 | 2.5 | 24.5 | 11 |
| 1 | 1 | 1 x 1.12 | 0.6 | 2.2 | 2.7 | 18.1 | 13 |
| 1.5 | 1 | 1 x 1.36 | 0.7 | 2.6 | 3.2 | 12.1 | 19 |
| 1.5 | 2 | 7 x 0.52 | 0.7 | 2.7 | 3.3 | 12.1 | 21 |
| 2.5 | 1 | 1 x 1.74 | 0.8 | 3.2 | 3.9 | 7.41 | 30 |
| 2.5 | 2 | 7 x 0.66 | 0.8 | 3.3 | 4 | 7.41 | 33 |
| 4 | 1 | 1 x 2.23 | 0.8 | 3.6 | 4.4 | 4.61 | 44 |
| 4 | 2 | 7 x 0.84 | 0.8 | 3.8 | 4.6 | 4.61 | 48 |
| 6 | 1 | 1 x 2.71 | 0.8 | 4.1 | 5 | 3.08 | 62 |
| 6 | 2 | 7 x 1.03 | 0.8 | 4.3 | 5.2 | 3.08 | 67 |
| 10 | 1 | 1 x 3.51 | 1 | 5.3 | 6.4 | 1.83 | 104 |
| 10 | 2 | 7 x 1.34 | 1 | 5.6 | 6.7 | 1.83 | 111 |
| 16 | 2 | 7 x 1.7 | 1 | 6.4 | 7.6 | 1.15 | 169 |
| 25 | 2 | 7 x 2.12 | 1.2 | 8.1 | 9.7 | 0.727 | 264 |
| 35 | 2 | 7 x 2.49 | 1.2 | 9 | 10.9 | 0.524 | 354 |