Specifications and structure of stranded and semi-conductive wires, according to NOOR wire and cable catalog.

Product features

Technical code
H05V-U ، H07V-U ، H07V - R ، NYA
ISIRI (607) 01
IEC 60227 05 (H05V - U)
IEC 60227 01 (H07V - U)
IEC 60227 01 (H07V - R)
NYA
Rated voltage (V)
For conductors up to 300 / 500 v
1 mm2
For conductors with a cross section greater than 450 / 750 v
1 mm2
Reference standard
ISIRI 607 - 3
ISIRI 60227 - 3
Temperature range (°C)
to-5 C
+70 C
Structure of layers
Cu / PVC

General description and specifications

Wire and semi-insulated wires with insulation
PVC
: Nominal voltage
For conductors up to 300 / 500 v
1 mm2
For conductors with a cross section greater than 450 / 750 v
1 mm2
: reference standard
ISIRI 607 - 3
ISIRI 60227 - 3
: SIM code
ISIRI (607) 01
IEC 60227 05 (H05V - U)
IEC 60227 01 (H07V - U)
IEC 60227 01 (H07V - R)
N.Y.A
: Temperature range
to-5 C
+70 C

Wire and cable structure

Wire structure
Cu/PVC
(Maftoli), for conductor 1, conductor type and grade: grade annealed copper
(semi-expanded) for 2 kidneys up to cross-sectional level and class
Conductor sizes, according to the national standard (IEC 60228) ISIRI 3084
Insulation material: mixed type
PVC
c
Insulation coloring: according to customer request
16 mm2

Applications

wire
. Simple production process 4. Low cost 3. Mechanical strength 2. Electrical conductivity 1: an obvious feature
Fixed wiring of the building
Talu industrial electricity distribution
Power transmission lines
Network cable
Semi-conductive wire
Feature: balance and shaping
Electrical switchboard connections - installation in ducts and trays - constant pressure electrical cables - fixed industrial equipment

Technical specification table

Technical specifications table — page 10
Nominal cross-sectional area of the conductormm²Conductor classNumber and diameter of conductor strandsNominal thickness of insulationmmLower limit of overall dimensionsmmUpper limit of overall dimensionsmmMaximum conductor ohmic resistance at ۲۰°CΩ/kmApproximate weightkg/km
0.511 x 0.80.61.92.3368
0.7511 x 0.950.62.12.524.511
111 x 1.120.62.22.718.113
1.511 x 1.360.72.63.212.119
1.527 x 0.520.72.73.312.121
2.511 x 1.740.83.23.97.4130
2.527 x 0.660.83.347.4133
411 x 2.230.83.64.44.6144
427 x 0.840.83.84.64.6148
611 x 2.710.84.153.0862
627 x 1.030.84.35.23.0867
1011 x 3.5115.36.41.83104
1027 x 1.3415.66.71.83111
1627 x 1.716.47.61.15169
2527 x 2.121.28.19.70.727264
3527 x 2.491.2910.90.524354
Main catalog tables — Product technical referenceجدول اصلی مشخصات فنی Solid and stranded wires