Outdoor underground telephone cables
Specifications and structure of telecommunication cables outside the building (ground), according to NOOR wire and cable catalog.
Product features
- Technical code
- A2Y (St) 2Y
TCI
VDE 0816
A2Y (St) 2Y - Temperature range (°C)
- to-30 C
+70 C
HDPE
500 V (AC)
: Maximum conductor resistance
For 65 / Km: 0.6
: Mutual capacitance
52 + 2 nf / Km - Minimum insulation resistance
- 20,000 M.Km
- Reference standard
- UV
2kV (AC) - Structure of layers
- Cu / HDPE / OSCR / HDPE
General description and specifications
string to shield
thread by thread
Telephone cables for wiring outside the building with insulation and
Aluminum cover and shield, resistant to radiation
: Maximum operating voltage
225 v
: Nominal voltage
Cable code:
TCI
VDE 0816
A2Y (St) 2Y
: Temperature range
to-30 C
+70 C
HDPE
500 V (AC)
: Maximum conductor resistance
For 65 / Km: 0.6
: Mutual capacitance
52 + 2 nf / Km
: Minimum insulation resistance
20,000 M.Km
: reference standard
UV
2kV (AC)
Wire and cable structure
Wire structure
Cu/HDPE/OSCR/HDPE
Wire 1, conductor material and class: annealed copper class
, and 5 or 4 types of insulating material: mix of brigade, class, group
According to the standard
PE
Identification of strands: two strands according to the standard color scheme to each other
radiated and form a couple. Then couples to each other
spun and a layer of polyester tape longitudinally or transversely for
An increase in insulation resistance is placed on them
Shield: An aluminum layer longitudinally or transversely as a shield
In contact with a single strand of plain copper or tin plated
Cover color: black
B
III
E8
ASTM D - 1248
, and from 5 or 4 types of coating: mix of brigade, class, group
According to the standard
PE
c
III
J3
ASTM D - 1248
Applications
In aerial routes between telecommunication towers or yachts
In the burial paths
In the basement ducts
Technical specification table
| Product type | Nominal diameter of the conductormm | Insulation type | Insulation thicknessmm | Coating thicknessmm | Average outer diametermm | Approximate weightkg/km |
|---|---|---|---|---|---|---|
| 2 x 2 x 0.6 | 0.6 | HDPE | 0.2 | 0.8 | 4.8 | 26 |
| 4 x 2 x 0.6 | 0.6 | HDPE | 0.2 | 0.8 | 6.1 | 42 |
| 6 x 2 x 0.6 | 0.6 | HDPE | 0.2 | 0.8 | 6.7 | 57 |
| 10 x 2 x 0.6 | 0.6 | HDPE | 0.2 | 1 | 8.1 | 85 |